MagniscreenMRI Protocols & Planning
Protocol Explorer

Neuro protocol

MRI Radiation Planning

Isotropic brain MRI for radiation oncology treatment planning. Uses a thermoplastic mask and board for patient immobilization. Primary sequence is isotropic 3D T1 postcontrast; T2 FS SPACE and FLAIR 3D are acquired for contouring. No fast alternatives for uncooperative patients.

neurobrainradiation planningradiation oncologyRT planningstereotacticisotropicconditional contrast

For protocol planning and internal reference only. Follow institutional MRI safety screening, contrast, dosage, and GFR policies.

Decision supportContrast GuidanceDefault contrast approach and conditional indications.

Contrast indications

No contrast indications listed.

Dose notes

  • Follow department policy regarding contrast administration and dosing.
  • Refer to policy regarding dosage and GFR deficiencies.
  • No additional 5-minute wait is required after contrast administration.
Acquisition listSequencesRequired and conditional series for the exam.
SequencePlanePhaseRequiredNotes
Localizer Sagittal/Coronal/AxialAnynoncontrastYesCenter at the glabella.
Axial 3D T1 +CaxialpostcontrastConditionalPrimary diagnostic sequence for radiation planning. Optional only when the lesion is non-enhancing. Isotropic: slice thickness <= 1.0 mm, voxel size 1.0 x 1.0 x 1.0 mm. Coverage must include air above the scalp and extend below the foramen magnum with balanced superior and inferior coverage.
Axial T2 FS SPACEaxialnoncontrastYesIsotropic: slice thickness <= 1.0 mm, voxel size 1.0 x 1.0 x 1.0 mm.
Axial FLAIR 3DaxialnoncontrastYesIsotropic: slice thickness <= 1.0 mm, voxel size 1.0 x 1.0 x 1.0 mm.
PositioningSlice PlanningPlane-specific planning instructions and guide images for technologists.

axial

Axial planning

  • Slice selection must be orthogonal (no angulation).
  • Coverage must include air above the scalp and extend below the foramen magnum with balanced superior and inferior coverage.
  • Field of view must cover the entire brain.
  • All sequences must use isotropic 1.0 x 1.0 x 1.0 mm voxels.
Anatomic extentCoverage RulesMinimum coverage expectations and alignment rules.

axial

Axial field of view

Cover the entire brain. Include air above the scalp and extend below the foramen magnum with balanced superior and inferior coverage.

TechniqueSuggested Technique SpecificationsPlane-level vendor-neutral guidance from the source protocol.

axial

slice thickness
<= 1.0 mm
voxel size
1.0 x 1.0 x 1.0 mm

General

voxel size
1.0 x 1.0 x 1.0 mm
slice selection
orthogonal
Conditional workflowSpecial SituationsAdjustments for contrast, hardware, and protocol-specific conditions.

Non-enhancing lesion

  • Axial 3D T1 postcontrast sequence is optional when the lesion does not enhance.
  • Acquire Axial T2 FS SPACE and Axial FLAIR 3D for planning in all cases.
Future detailAdvancedSource-backed scanner, vendor, and site-specific notes when available.

Advanced technical details, scanner variants, and planning guide assets can appear here as protocol data expands.